DocumentCode :
813475
Title :
Alternatives for assessing the electrical integrity of induction motors
Author :
Kohler, Jeffery L. ; Sottile, Joseph ; Trutt, Frederick C.
Author_Institution :
Dept. of Miner. Eng., Pennsylvania State Univ., University Park, PA, USA
Volume :
28
Issue :
5
fYear :
1992
Firstpage :
1109
Lastpage :
1117
Abstract :
The use of periodic inspection methods for early detection of motor deterioration is addressed. Two alternatives to traditional procedures that are appropriate for detecting stator-winding deterioration in three-phase induction motors of the sizes commonly found in the process industries are presented. The use of an effective-negative-sequence impedance as a predictor of incipient failure is recommended
Keywords :
induction motors; inspection; machine testing; stators; 3-phase induction motors; early deterioration detection; effective-negative-sequence impedance; electrical integrity; periodic inspection methods; stator-winding deterioration; Condition monitoring; Costs; Induction motors; Inspection; Insulation testing; Performance evaluation; Personnel; Predictive maintenance; Safety; Senior members;
fLanguage :
English
Journal_Title :
Industry Applications, IEEE Transactions on
Publisher :
ieee
ISSN :
0093-9994
Type :
jour
DOI :
10.1109/28.158836
Filename :
158836
Link To Document :