DocumentCode
813936
Title
A Measuring System for Studying the Time-Resolution Capabilities of Fast Photomultipliers
Author
Lo, C.C. ; Leskovar, B.
Author_Institution
Lawrence Berkeley Laboratory University of California Berkeley, California 94720
Volume
21
Issue
1
fYear
1974
Firstpage
93
Lastpage
105
Abstract
A measuring system has been developed for studying and optimizing the time-resolution capabilities of fast photoelectric devices, such as standard and microchannel type photomultipliers. The system incorporates a subnanosecond light-pulse generator capable of operating at repetition frequencies up to 3 MHz with output light pulses having a full width at half-maximum of less than 200 psec, and a zero-crossing discriminator which has a time walk of ±40 psec over a 170 mV to 8 V input-pulse amplitude variation. Averaging the data from several successive measurements, the measuring system time resolution is 20 psec.
Keywords
Anodes; Cathodes; Instruments; Photomultipliers; Pulse generation; Pulse measurements; Pulse width modulation converters; Spectroscopy; Time measurement; Timing;
fLanguage
English
Journal_Title
Nuclear Science, IEEE Transactions on
Publisher
ieee
ISSN
0018-9499
Type
jour
DOI
10.1109/TNS.1974.4327450
Filename
4327450
Link To Document