  • Title

    Large Area Reach-Through Avalanche Diodes for Radiation Monitoring

  • Author

    Webb, P. ; Jones, A.R.

  • Author_Institution
    RCA Limited, R&D Laboratories Ste. Ane-de-Bellevue, Quebec, Canada
  • Volume
    21
  • Issue
    1
  • fYear
    1974
  • Firstpage
    151
  • Lastpage
    158
  • Abstract
    Avalanche diodes, up to 20 mm2 in area, have been made with sensitivities up to 6 × 106 counts/ Roentgen. Operating at 200 volts, typical gains of 20 are achieved. This permits the detection of 6 keV X-rays and dosimetry of gamma rays down to 30 keV with background counting rates of about 0.1 c/s.
  • Keywords
    Dosimetry; Gamma ray detection; Gamma ray detectors; Gamma rays; Laboratories; Leakage current; Radiation monitoring; Rivers; Schottky diodes; Silicon;
  • fLanguage
    English
  • Journal_Title
    Nuclear Science, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9499
  • Type

    jour

  • DOI
    10.1109/TNS.1974.4327455
  • Filename