Title : 
Determination of thyristor reverse recovery current parameters
         
        
            Author : 
Lee, Chang Woo ; Park, Song Bai
         
        
            Author_Institution : 
Dept. of Electr. Eng., Korea Adv. Inst. of Sci. & Technol., Seoul, South Korea
         
        
        
        
        
            fDate : 
3/1/1988 12:00:00 AM
         
        
        
        
            Abstract : 
The authors describe a method of determination of reverse recovery current parameters of the thyristor turnoff model, namely, the peak reverse recovery current and its decay time constant. The parameters are determined from a set of recovered charge curves, and another set of reverse energy loss curves, usually given in the manufacturer´s data sheet so that the curves may be fitted over a wide range of di/ dt at zero current and peak forward thyristor IF , just before its current reversal. In the parameter extraction, the storage time and the ratio of fall time to storage time were assumed to be functions of di/dt and IF. For various thyristors, the extracted parameters fit both sets of the above-mentioned curves within an error of 8% over a 1:100 ratio of di/dt at zero current and over a 1:4 ratio of I F
         
        
            Keywords : 
semiconductor device models; thyristors; current reversal; decay time constant; fall time; parameter extraction; peak reverse recovery current; recovered charge curves; reverse energy loss curves; reverse recovery current parameters; storage time; thyristor turnoff model;
         
        
        
            Journal_Title : 