Abstract :
In this paper, the degradation processes in stator-bar groundwall insulation that is subjected to steep-front voltage pulses, at different temperatures, are studied. The test conditions include pulse voltage amplitudes up to 6kVp and pulse switching frequencies up to 3 kHz in ambient temperatures of 23degC , 120degC , and 155degC . During the aging process, the surface temperature is monitored with an infrared camera to determine the regions with highest temperatures and the partial discharge (PD) activity. The visual examination of failed bars confirmed that the groundwall insulation in these regions is degraded.
Keywords :
ageing; induction motors; insulation testing; machine insulation; machine testing; monitoring; partial discharges; stators; aging process; degradation process; fast repetitive steep-front voltage pulse; groundwall insulation test; induction motor; infrared camera; medium-voltage stator coils; partial discharge; surface temperature monitoring; temperature 120 C; temperature 155 C; temperature 23 C; Aging; Coils; Degradation; Insulation; Medium voltage; Partial discharges; Stators; Switching frequency; Temperature; Testing; Adjustable-speed drives; converters; dielectric heating; groundwall insulation; induction motor; partial discharge (PD); pulse voltage; solid-state switches;
fLanguage :
English
Journal_Title :
Industry Applications, IEEE Transactions on
Publisher :
ieee
ISSN :
0093-9994
Type :
jour
DOI :
10.1109/TIA.2008.926305
Filename :
4578787
Link To Document :
بازگشت