DocumentCode
815895
Title
Neutron Spectrometry by Diamond Detector for Nuclear Radiation
Author
Kozlov, S.F. ; Konorova, E.A. ; Barinov, A.L. ; Jarkov, V.P.
Author_Institution
P.N. Lebedev Physical Institute, USSR Academy of Sciences Moscow, USSR
Volume
22
Issue
1
fYear
1975
Firstpage
171
Lastpage
172
Abstract
Experiments on fast neutron spectrometry using the nuclear radiation diamond detector inside a horizontal channel of a water-cooled and water-moderated reactor are described. It is shown that the diamond detector enables neutron spectra to be measured within the energy range of 0.3 - 10MeV against reactor gamma-radiation background and has radiation resistance higher than that of conventional semiconductor detectors.
Keywords
Assembly; Gamma ray detection; Gamma ray detectors; Inductors; Neutrons; Protons; Radiation detectors; Semiconductor radiation detectors; Spectroscopy; Time measurement;
fLanguage
English
Journal_Title
Nuclear Science, IEEE Transactions on
Publisher
ieee
ISSN
0018-9499
Type
jour
DOI
10.1109/TNS.1975.4327635
Filename
4327635
Link To Document