Title :
Experimental verification of bremsstrahlung production and dosimetry predictions for 15.5 MeV electrons
Author :
Sanford, T.W.L. ; Beutler, D.E. ; Halbleib, J.A. ; Knott, D.P.
Author_Institution :
Sandia Nat. Lab., Albuquerque, NM, USA
fDate :
12/1/1991 12:00:00 AM
Abstract :
The radiation produced by a 15.5-MeV monoenergetic electron beam incident on optimized and nonoptimized bremsstrahlung targets is characterized using the ITS Monte Carlo code and measurements with equilibrated and nonequilibrated TLD dosimetry. Comparisons between calculations and measurements verify the calculations and demonstrate that the code can be used to predict both bremsstrahlung production and TLD response for radiation fields that are characteristic of those produced by pulsed simulators of gamma rays. The comparisons provide independent confirmation of the validity of the TLD calibration for photon fields characteristic of gamma-ray simulators. The empirical Martin equation, which is often used to calculate radiation dose from optimized bremsstrahlung targets, is examined, and its range of validity is established
Keywords :
Monte Carlo methods; bremsstrahlung; dosimetry; electron beam effects; gamma-ray detection and measurement; 15.5 MeV; ITS Monte Carlo code; TLD dosimetry; bremsstrahlung production; empirical Martin equation; gamma-ray simulators; monoenergetic electron beam; Dosimetry; Electron accelerators; Electron beams; Energy measurement; Laboratories; Monte Carlo methods; Production; Pulse measurements; Saturn; X-rays;
Journal_Title :
Nuclear Science, IEEE Transactions on