Title : 
Nuclear Detection Instrumentation for Reactivity Measurements with the Fast Flux Test Facility Engineering Mockup Core
         
        
            Author : 
Mathis, M.V. ; De Lorenzo, J.T. ; Chiles, M.M. ; Mihalczo, J.T.
         
        
            Author_Institution : 
Oak Ridge National Laboratory Oak Ridge, Tennessee 37830
         
        
        
        
        
        
        
            Abstract : 
Four multichannel detection systems, two operating in an integrated current mode and two in a pulse mode within the engineering mockup core for the Fast Flux Test Facility reactor, successfully furnished signals during a 5-month reactivity surveillance procedures experiment for evaluation of reactivity measurement methods and associated instrumentation for Liquid Metal Fast Breeder Reactor applications. In addition, the adequacy of the low level flux monitor desigin for the Fast Flux Test Facility was verified.
         
        
            Keywords : 
Inductors; Instruments; Laboratories; Monitoring; Noise measurement; Nuclear measurements; Pulse measurements; Radiation detectors; System testing; Test facilities;
         
        
        
            Journal_Title : 
Nuclear Science, IEEE Transactions on
         
        
        
        
        
            DOI : 
10.1109/TNS.1975.4327730