Title : 
Design Parameters and Test Results for a Fission Counter Intended for Operation up to 750°F at High Gamma Dose Rates
         
        
            Author : 
Pare, V.K. ; Clay, W.T. ; De Lorenzo, J.T. ; Guerrant, G.C.
         
        
            Author_Institution : 
Oak Ridge National Laboratory Oak Ridge, Tennessee 37830
         
        
        
        
        
        
        
            Abstract : 
A fission counter was built and successfully tested for operation at 750°F and gamma dose rates up to 6 à 106 R/hr. Results from gamma and neutron tests were compared with theoretical predictions and used to optimize the performance of the counters.
         
        
            Keywords : 
Cables; Coatings; Counting circuits; Electrodes; Electromagnetic interference; Inductors; Monitoring; Neutrons; Radiation detectors; Testing;
         
        
        
            Journal_Title : 
Nuclear Science, IEEE Transactions on
         
        
        
        
        
            DOI : 