• DocumentCode
    818143
  • Title

    An innovative scintillation process for correcting, cooling, and reducing the randomness of waveforms

  • Author

    Shen, Jing

  • Author_Institution
    Inst. of High Energy Phys., Acad. Sinica, Beijing, China
  • Volume
    38
  • Issue
    6
  • fYear
    1991
  • fDate
    12/1/1991 12:00:00 AM
  • Firstpage
    1773
  • Lastpage
    1785
  • Abstract
    An innovative scintillation technique for high-energy collider detection is presented. A scintillation counter incorporating long scintillators with light guides, a drift chamber, and fast discriminators plus integrators was employed to resolve problems of correcting time walk and reducing the additional jitter by establishing an analytical waveform description of V(t,z) for a measured (z). The latter was accomplished by reducing jitter by compressing V(t,z) with a nonlinear medium, called cooling scintillation. Quantum fluctuations of luminescence were dealt with by orienting molecular and polarizing scintillation through the use of intense magnetic technology, called stabilizing the waveform
  • Keywords
    discriminators; nuclear electronics; scintillation counters; cooling scintillation; drift chamber; fast discriminators; high-energy collider detection; integrators; intense magnetic technology; jitter; luminescence; scintillation counter; scintillation technique; time walk; Cooling; Dispersion; Frequency; IEEE activities; Jitter; Magnetic analysis; Pulse shaping methods; Sampling methods; Shape; Solid scintillation detectors;
  • fLanguage
    English
  • Journal_Title
    Nuclear Science, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9499
  • Type

    jour

  • DOI
    10.1109/23.124175
  • Filename
    124175