DocumentCode
818769
Title
Comparison of Cold and Warm Vacuum Systems for Intersecting Storage Rings
Author
Halama, H.J. ; Herrera, J.C.
Author_Institution
Brookhaven National Laboratory Upton, New York 11973
Volume
22
Issue
3
fYear
1975
fDate
6/1/1975 12:00:00 AM
Firstpage
1492
Lastpage
1495
Abstract
In storage rings employing superconducting magnets, the use of a cold bore as a cryopump appears, at first glance, as simple and economical. Since the selection of a cold or warm vacuum system has far-reaching implications on the basic design, we consider each system in some detail. The theoretical and practical limitations imposed on the maximum beam current by the gas desorption from the chamber walls are discussed. A realistic design of a cold vacuum chamber is developed and then compared with the proposed warm ISABELLE vacuum system. The comparison shows that the warm approach is preferable.
Keywords
Boring; Electrodes; Electron beams; Laboratories; Laser excitation; Particle beams; Storage rings; Structural beams; Superconducting magnets; Vacuum systems;