• DocumentCode
    819070
  • Title

    LLL 100-MeV Electron Linac: Design Considerations and Performance of the Beam-Transport Vacuum System

  • Author

    Lara, M.C. ; Brooks, H.E.

  • Author_Institution
    Lawrence Livermore Laboratory, University of California Livermore, California 94550
  • Volume
    22
  • Issue
    3
  • fYear
    1975
  • fDate
    6/1/1975 12:00:00 AM
  • Firstpage
    1609
  • Lastpage
    1612
  • Abstract
    This paper describes the vacuum system for the beam-transport lines used with the Lawrence Livermore Laboratory 100-MeV electron-positron linear accelerator. It is operated in the high (10-4 to 10-5 Pa) range using standard ion pumps with turbomolecular pumps for roughdown. This paper also reviews the important factors considered during the initial design phases; these factors have contributed to the very reliable performance of the vacuum system since its startup five years ago. The cleaning and handling procedures used on the beam-transport lines, magnet vacuum chambers, and other vacuum components are discussed.
  • Keywords
    Design engineering; Electron beams; Laboratories; Laser excitation; Linear accelerators; Linear particle accelerator; Reliability engineering; Steel; Structural beams; Vacuum systems;