    Radiation-tolerant Raman distributed temperature monitoring system for large nuclear infrastructures

  • Author

    Fernandez, A. Fernandez ; Rodeghiero, P. ; Brichard, B. ; Berghmans, F. ; Hartog, A.H. ; Hughes, P. ; Williams, K. ; Leach, A.P.

  • Author_Institution
    SCKCEN, Belgian Nucl. Res. Centre, Mol, Belgium
  • Volume
    52
  • Issue
    6
  • fYear
    2005
  • Firstpage
    2689
  • Lastpage
    2694
  • Abstract
    Raman Distributed Temperature Sensors (RDTS) are attractive for the monitoring of large structures in nuclear power plants such as containment structures and coolant loop systems. We demonstrate the high radiation tolerance of a Raman distributed fiber optic temperature sensor, up to total gamma doses in excess of 300 kGy, using a double-ended configuration and commercially-available optical fibers.
  • Keywords
    Raman spectra; dosimetry; fibre optic sensors; gamma-ray effects; nuclear power stations; radiation monitoring; temperature sensors; 300 kGy; Raman distributed fiber optic temperature sensor; Raman scattering; coolant loop systems; gamma doses; gamma radiation; large nuclear infrastructures; nuclear power plants; optical fiber sensing; radiation effects; radiation tolerance; radiation-tolerant raman; temperature monitoring system; Electricity supply industry; Fuel processing industries; Leak detection; Optical attenuators; Optical fiber sensors; Optical fibers; Power generation; Radiation monitoring; Temperature measurement; Temperature sensors; Gamma radiation; Raman scattering; optical fiber sensing; radiation effects; temperature nuclear power plant;
  • fLanguage
    English
  • Journal_Title
    Nuclear Science, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9499
  • Type

    jour

  • DOI
    10.1109/TNS.2005.860736
  • Filename
    1589258