DocumentCode :
819346
Title :
An improved technique of impedance measurement for thin film inductors over 10 MHz
Author :
Arai, K.I. ; Yamaguchi, M. ; Ohzeki, H.
Author_Institution :
Res. Inst. of Electr. Commun., Tohoku Univ., Sendai, Japan
Volume :
28
Issue :
5
fYear :
1992
fDate :
9/1/1992 12:00:00 AM
Firstpage :
2175
Lastpage :
2177
Abstract :
The accuracy of the impedance measurement for thin-film inductors over 10 MHz is discussed. It is necessary for accurate measurement to prepare an appropriate fixture. A fixture with precise dimensions permits impedance matching between the inductor and the measurement instrument. The inductor is placed on a ground plane of microstrip line and it is connected to a network analyzer through a transmission line. An improved system has been developed to measure the impedance of thin-film inductors accurately up to 500 MHz
Keywords :
electric impedance measurement; impedance matching; inductors; network analysers; 10 to 500 MHz; ground plane; impedance matching; impedance measurement; measurement instrument; microstrip line; network analyzer; thin film inductors; Capacitance; Coaxial components; Conductors; Connectors; Electric variables measurement; Fixtures; Impedance measurement; Microstrip; Power transmission lines; Thin film inductors;
fLanguage :
English