• DocumentCode
    819537
  • Title

    Tuning of the First Section of the Biomedical Channel at LAMPF

  • Author

    Paciotti, M.A. ; Bradbury, J.N. ; Helland, J.A. ; Hutson, R.L. ; Knapp, E.A. ; Rivera, O.M. ; Knowles, H.B. ; Pfeufer, G.

  • Author_Institution
    University of California Los Alamos Scientific Laboratory Los Alamos, NM 87544
  • Volume
    22
  • Issue
    3
  • fYear
    1975
  • fDate
    6/1/1975 12:00:00 AM
  • Firstpage
    1784
  • Lastpage
    1789
  • Abstract
    Results are presented from the tuning of the first section of the Biomedical Channel at LAMPF; the work centers about the use of the third bending magnet as a magnetic spectrometer. The momentum resolution at the intermediate focus is given in detail. The performance of a wedge degrader that compresses the wide momentum acceptance of the first section is discussed. The output ¿- rate is also given.
  • Keywords
    Data acquisition; Degradation; Laboratories; Optical scattering; Particle beams; Particle scattering; Production; Solids; Spatial resolution; Spectroscopy;
  • fLanguage
    English
  • Journal_Title
    Nuclear Science, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9499
  • Type

    jour

  • DOI
    10.1109/TNS.1975.4327992
  • Filename
    4327992