DocumentCode :
819817
Title :
Effect of azimuth angle and bias field on second harmonic distortion in differentially biased MR heads
Author :
Dee, Richard H.
Author_Institution :
Storage Technol. Corp., Louisville, CO, USA
Volume :
28
Issue :
5
fYear :
1992
fDate :
9/1/1992 12:00:00 AM
Firstpage :
2298
Lastpage :
2300
Abstract :
Measurement of the azimuth dependence of the second harmonic distortion (SHD) in magnetoresistive (MR) heads is presented. The use of differential biasing and sensing is one method of eliminating SHD by perfect cancellation of distortion signals from two half-elements oppositely biased. However, when some azimuth angle between the MR element and recorded signals is introduced, the SHD rapidly increases due to an imbalance in the input signal strength for each half-element. The effect of bias field and data on single end biased elements is given
Keywords :
electric distortion; magnetic heads; magnetoresistive devices; azimuth angle; bias field; differential biasing; distortion signal cancellation; input signal strength; magnetoresistive heads; oppositely biased half-elements; second harmonic distortion; sensing; single end biased elements; Azimuth; Distortion measurement; Equations; Geometry; Harmonic distortion; Linear approximation; Magnetic field measurement; Magnetic heads; Magnetic recording; Magnetoresistance;
fLanguage :
English
Journal_Title :
Magnetics, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9464
Type :
jour
DOI :
10.1109/20.179474
Filename :
179474
Link To Document :
بازگشت