DocumentCode :
81996
Title :
Effects of Vehicle Running Mode on Rail Potential and Stray Current in DC Mass Transit Systems
Author :
Shao-Yi Xu ; Wei Li ; Yu-Qiao Wang
Author_Institution :
Sch. of Mech. & Electr. Eng., China Univ. of Min. & Technol., Xuzhou, China
Volume :
62
Issue :
8
fYear :
2013
fDate :
Oct. 2013
Firstpage :
3569
Lastpage :
3580
Abstract :
The ungrounded scheme with overvoltage protection device (OVPD) has been adopted in the construction of Nanjing Metro Line 1. During the operation of Line 1, a high rail potential was observed, which caused the OVPDs installed at some traction supply substations (TSSs) to keep turning on at any moment, and the stray-current leakage increased obviously. Since the magnitude of rail potential and stray current depends on the modes of a running vehicle, including accelerating, coasting, constant speed, or braking, Line 1 suspected that the vehicle running modes were the cause of a potential rise in the rail. This paper presents the results of field tests and numerical simulations to study whether different vehicle running modes have an impact on rail potential and stray current in Line 1. The results show that the rail potential in the acceleration and brake modes is significantly higher than that in the other modes, which are in the opposite direction. Moreover, within the stray-current interference, the maximum shifts of buried-conductor potential may exceed the limit in these two modes. In addition, the high rail potential and buried-conductor potential occur when the running mode changes from acceleration to coasting or the maximum brake power is reached. As a vehicle is running between two different TSSs, the rail potential is highest in its position.
Keywords :
electric locomotives; overvoltage protection; railway electrification; Nanjing Metro Line 1; OVPD; TSS; acceleration mode; brake mode; buried-conductor potential; coasting mode; constant speed mode; dc mass transit systems; overvoltage protection device; rail potential; stray current leakage; stray-current interference; traction supply substations; vehicle running mode; Acceleration; Conductors; Electric potential; Rails; Roads; Substations; Vehicles; Direct-current (DC) mass transit system; overvoltage protection device (OVPD); rail potential; stray current; vehicle running mode;
fLanguage :
English
Journal_Title :
Vehicular Technology, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9545
Type :
jour
DOI :
10.1109/TVT.2013.2265093
Filename :
6522151
Link To Document :
بازگشت