DocumentCode
821211
Title
Neutron-Induced Dose Enhancement in Tantalum
Author
Lurie, N.A. ; Harris, L., Jr. ; Steinman, D.K. ; Young, J.C. ; Friesenhahn, S.J. ; Wondra, J.P.
Author_Institution
IRT Corporation, San Diego, California
Volume
22
Issue
6
fYear
1975
Firstpage
2573
Lastpage
2575
Abstract
Local dose enhancement caused by neutron capture in tantalum devices has been predicted but not previously measured. An experiment is reported in which the dose due to conversion electrons and sub-MeV photons resulting from neutron capture in Ta is compared to the dose from high-energy photons. For measurements on a thin Ta foil using a silicon surface barrier detector and incident neutrons in the resonance region (thermal to 500 eV), the dose enhancement ratio (dose due to all secondary radiations/dose due to super-MeV photons) was found to be 4.7 ± 0.3.
Keywords
Design optimization; Electrons; Filters; Lead; Neutrons; Particle beams; Performance evaluation; Radiation detectors; Resonance; Silicon radiation detectors;