• DocumentCode
    821514
  • Title

    Fast extraction of positive-sequence current from harmonically corrupted three-phase currents for TCR compensator control systems

  • Author

    Ho, P.T. ; Tso, S.K.

  • Author_Institution
    Dept. of Electr. & Electron. Eng., Hong Kong Univ., Hong Kong
  • Volume
    37
  • Issue
    1
  • fYear
    1990
  • Firstpage
    82
  • Lastpage
    85
  • Abstract
    The authors discuss a practical scheme for extracting the magnitude of the positive-sequence component from harmonically corrupted three-phase currents found in modern energy systems. The scheme is cost-effective, fast, and simple in design, with the novel combination of software processing and digital and analog circuits. The scheme has been successfully applied to a microprocessor-based thyristor-controlled reactor (TCR) control system and is suitable for similar real-time applications that already include one or more processing units. It is demonstrated that the scheme is adequately fast for the TCR control system because the extraction delay is typically less than half a cycle. The scheme is especially suitable for microprocessor-based control systems because the averaging function can be advantageously performed by software.<>
  • Keywords
    compensation; harmonics; microcomputer applications; power system computer control; reactive power; thyristor applications; control system; extraction delay; harmonically corrupted three-phase currents; microprocessors; positive-sequence component; power system computer control; reactive power compensation; software processing; thyristor-controlled reactor;
  • fLanguage
    English
  • Journal_Title
    Industrial Electronics, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0278-0046
  • Type

    jour

  • DOI
    10.1109/41.45847
  • Filename
    45847