DocumentCode :
821933
Title :
A Low Power CAMAC Drift Chamber Time Digitizer System
Author :
Droege, T.F. ; Watson, M.M. ; Wesson, T.R.
Author_Institution :
Fermi National Accelerator Laboratory P. O. Box 500 Batavia, Illinois 60510
Volume :
23
Issue :
1
fYear :
1976
Firstpage :
247
Lastpage :
250
Abstract :
A Drift Chamber Time Digitizer System has been designed which combines direct counting and time stretching techniques. By time stretching for only the low order bits, most logic can be low power Schottky TTL allowing 3 channels of 3 ns time resolution in a single width CAMAC module while holding conversion time to less than 1¿s.
Keywords :
CAMAC; Capacitors; Clocks; Costs; Counting circuits; Energy resolution; Laboratories; Logic; Pulse measurements; Time measurement;
fLanguage :
English
Journal_Title :
Nuclear Science, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9499
Type :
jour
DOI :
10.1109/TNS.1976.4328247
Filename :
4328247