DocumentCode
822062
Title
A Wide Range Counting-Campbelling Nuclear Instrumentation System
Author
Oda, M. ; Wada, M. ; Badono, S.
Author_Institution
Central Research Laboratory Mitsubishi Electric Corporation Minami-Shimizu, Amagasaki, Japan
Volume
23
Issue
1
fYear
1976
Firstpage
303
Lastpage
306
Abstract
Feature of the present system is the use of the developed low noise current-sensitive preamplifier, counting loss compensation pulse rate-meter and fast response true-mean-square circuit. Noise level of the preamplifier is 10 PA/¿Hz for 30 cable system. True mean square circuit operated at 100 KHz has a response time constant of 10 msec and a wide output range over 6 decades without level switching.