Title :
A Liquid Level Detector for Reactor Environments
Author :
Goodrich, L.D. ; Arave, A.E.
Author_Institution :
Idaho National Engr. Laboratory Idaho Falls, Idaho 83401 208-526-0111 ext. 1680, 8211
Abstract :
A conductivity-sensitive liquid level detector has been desianed for the pressurized water reactor environment of the Loss-of-Fluid Test (LOFT) reactor at the Idaho National Engineering Laboratory. Test results indicate the detector is not only capable of indicating liquid level, but also oscillatory behavior in the two-phase fluid. Test data are presented along with a brief description of the detector design.
Keywords :
Conductivity; Detectors; Electrodes; Inductors; Land surface temperature; Level measurement; Seals; Switches; Testing; Transducers;
Journal_Title :
Nuclear Science, IEEE Transactions on
DOI :
10.1109/TNS.1976.4328275