DocumentCode
82281
Title
Correlation between transfer impedance and insertion loss of current probes
Author
Lijun Yao ; Weiyu Ma ; Canyi Yu
Author_Institution
Electromagn. Environ. Effect Lab., Beijing Inst. of Radio Metrol. & Meas., Beijing, China
Volume
3
Issue
2
fYear
2014
fDate
2nd Quarter 2014
Firstpage
51
Lastpage
55
Abstract
Transfer impedance and insertion loss are two important performance parameters of current probes. In this paper the relationship between them is discussed and analyzed. First the analysis is carried out from the aspect of their definitions. Then the two parameters are analyzed from physical aspects. Preliminary experimental validation is presented in this paper whereafter. The measurement results have shown a satisfactory verification.
Keywords
electric current measurement; electric sensing devices; current measurement; current probe; insertion loss; transfer impedance; Analytical models; Clamps; Couplers; Current probes; Impedance; Insertion loss; Loss measurements; Receivers; current clamp; current injection probe; current probe; insertion loss; transfer impedance;
fLanguage
English
Journal_Title
Electromagnetic Compatibility Magazine, IEEE
Publisher
ieee
ISSN
2162-2264
Type
jour
DOI
10.1109/MEMC.2014.6849544
Filename
6849544
Link To Document