• DocumentCode
    822828
  • Title

    A Microprocessor Based Environmental Radiation Monitoring System

  • Author

    McCormick, Dan J. ; Glesius, Fred L. ; Kroon, John C.

  • Author_Institution
    Reuter-Stokes, Inc. Cleveland, Ohio
  • Volume
    23
  • Issue
    1
  • fYear
    1976
  • Firstpage
    710
  • Lastpage
    714
  • Abstract
    A multisensor environmental radiation monitoring system utilizing pressurized ionization chambers is described. The system is capable of measuring incremental increases in gamma radiation exposure of the order of 1 mrad/year due to gaseous effluents from nuclear power plants. Continuous monitoring at a number of sites at or beyond the reactor boundary is performed automatically under control of a microprocessor-based central data acquisition facility. The exposure rate record from each sensor is reduced to a convenient form which can be used to easily determine the reactor plume contribution to the total exposure.
  • Keywords
    Computerized monitoring; Effluents; Gamma rays; Inductors; Ionization chambers; Microprocessors; Nuclear measurements; Power generation; Power measurement; Radiation monitoring;
  • fLanguage
    English
  • Journal_Title
    Nuclear Science, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9499
  • Type

    jour

  • DOI
    10.1109/TNS.1976.4328332
  • Filename
    4328332