DocumentCode
823413
Title
Angular dependent recording behavior of ME tape
Author
Richter, H.J. ; Schildberg, H.P. ; Hibst, H.
Author_Institution
BAF AG, Ludwigschafen, Germany
Volume
28
Issue
5
fYear
1992
fDate
9/1/1992 12:00:00 AM
Firstpage
3288
Lastpage
3290
Abstract
The recording behavior of metal evaporated (ME) tape as a function of the angle between the direction of recording and the usual running direction of the tape is investigated in detail. It is found that the output-vs-angle curves exhibit a shift and a narrowing of the peak centered at about the normal recording direction as well as a broadening of the peak centered at the opposite direction. This is explained by a combination of remanence loss effects and the relevant head field gradients at the wiring point
Keywords
magnetic recording; magnetic tapes; remanence; ME tape; angular dependence; head field gradients; metal evaporated tape; normal recording direction; recording behavior; remanence loss effects; running direction; Goniometers; Loss measurement; Magnetic heads; Q measurement; Remanence; Saturation magnetization; Shape measurement; Testing; Vectors; Writing;