• DocumentCode
    825622
  • Title

    Automatic Error Compensatton in DC Amplifiers

  • Author

    Longden, L.L.

  • Author_Institution
    IRT Corporation San Diego, California
  • Volume
    23
  • Issue
    6
  • fYear
    1976
  • Firstpage
    2045
  • Lastpage
    2048
  • Abstract
    When operational amplifiers are exposed to high levels of neutron fluence or total ionizing dose, significant changes may be observed in input voltages and currents. These changes may produce large errors at the output of direct-coupled amplifier stages. Therefore, the need exists for automatic compensation techniques. Hlowever, previously introduced techniques compensate only for errors in the main amplifier and neglect the errors induced by the compensating circuitry. In this paper, the techniques introduced compensate not only for errors in the main operational amplifier, but also for errors induced by the compensation circuitry. Included in the paper is a theoretical analysis of each compensation technique, along with advantages and disadvantages of each. Important design criteria and information necessary for proper selection of semiconductor switches will also be included. Introduced in this paper will be compensation circuitry for both resistive and capacitive feedback networks.
  • Keywords
    Data acquisition; Error correction; Feedback circuits; Filtering; Neutrons; Operational amplifiers; Sampling methods; Switches; Transfer functions; Voltage;
  • fLanguage
    English
  • Journal_Title
    Nuclear Science, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9499
  • Type

    jour

  • DOI
    10.1109/TNS.1976.4328622
  • Filename
    4328622