• DocumentCode
    826133
  • Title

    Contribution of the Channel Electron Multiplier to the Race of Vacuum Tubes Towards Picosecond Resolution Time

  • Author

    Pietri, G.

  • Author_Institution
    Laboratoires d´´Electronique et de Physique Appliquée 3, avenue Descartes 94450 Limeil-Brévannes, France
  • Volume
    24
  • Issue
    1
  • fYear
    1977
  • Firstpage
    228
  • Lastpage
    232
  • Abstract
    The ability to tightly pack millions of microscopic secondary emitting channels into a two-dimensional, very thin, array known as a microchannel plate (MCP) provides excellent electrical charge or current amplification associated with an extremely short response time as well as very good spatial resolution. The ultimate performances in spatial and temporal resolutions achieved by MCP-based vacuum devices are discussed and illustrated by the description of a large range of experimental prototypes (photomultipliers, oscilloscope tubes, streak camera tubes, etc.) designed and produced at LEP, then tested in cooperation with Nuclear Research and Plasma Physics Centers in Europe and USA.
  • Keywords
    Delay; Electron multipliers; Electron tubes; Microchannel; Microscopy; Oscilloscopes; Performance evaluation; Photomultipliers; Prototypes; Spatial resolution;
  • fLanguage
    English
  • Journal_Title
    Nuclear Science, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9499
  • Type

    jour

  • DOI
    10.1109/TNS.1977.4328676
  • Filename
    4328676