    Accuracy of ground-based microwave radiometer and balloon-borne measurements during the WVIOP2000 field experiment

  • Author

    Cimini, Domenico ; Westwater, Ed R. ; Han, Yong ; Keihm, Stephen J.

  • Author_Institution
    CETEMPS, L´´Aquila Univ., Italy
  • Volume
    41
  • Issue
    11
  • fYear
    2003
  • Firstpage
    2605
  • Lastpage
    2615
  • Abstract
    We discuss the performances of a set of four microwave water vapor radiometers operating in the 20-30-GHz band during a field experiment, with an emphasis on calibration and achievable accuracy. The field experiment was conducted at the Department of Energy\´s Atmospheric Radiation Measurement Program\´s field site in north central Oklahoma, and was focused on clear-sky water vapor measurements by both radiometers and radiosondes. A comparison between two published radiometric tip curve calibration procedures is presented, and these procedures are applied to measurements from two nearly identical instruments placed a few meters apart. Using the instantaneous tip cal method of the Environmental Technology Laboratory, the brightness temperature measurements for the two identical instruments differed by less than 0.2 K over a 24-h period. Results from reference load cryogenic tests and brightness temperature cross comparisons have shown differences within 0.7 K. In addition, we compare radiometric measurements with calculations of brightness temperature based on the Rosenkranz absorption model and radiosonde observations. During the experiment, both Vaisala-type RS80 and RS90 humidity sensors were used. Our comparisons demonstrate the improvements achieved by the new Vaisala RS90 sensors in atmospheric humidity profiling, which reduce or eliminate the "dry bias" problem.
  • Keywords
    atmospheric humidity; atmospheric techniques; calibration; radiometry; 20 to 30 GHz; Rosenkranz absorption model; WVIOP2000 field experiment; balloon-borne measurements; calibration procedures; ground-based microwave radiometer measurements; humidity sensors; instantaneous tip cal method; microwave water vapor radiometers; radiometric measurements; radiosonde observations; Atmospheric measurements; Brightness temperature; Calibration; Cryogenics; Energy measurement; Humidity; Instruments; Microwave measurements; Microwave radiometry; Temperature measurement;
  • fLanguage
    English
  • Journal_Title
    Geoscience and Remote Sensing, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0196-2892
  • Type

    jour

  • DOI
    10.1109/TGRS.2003.815673
  • Filename
    1245248