DocumentCode
827082
Title
A Threshold Self-Powered Gamma Detector for Use as a Nuclear Reactor Power Monitor
Author
LeVert, F.E.
Author_Institution
Applied Physics Divisim, Argonne National Laboratory
Volume
24
Issue
1
fYear
1977
Firstpage
683
Lastpage
686
Abstract
A study of a threshold self-powered gamma detector for use as a nuclear reactor power monitor was conducted. Measurements were performed to ascertain whether certain detector material arrangements could be used to obtain significant discrimination against low energy gammas. Results indicating agreement between detector response and reactor power output are presented. Evidence of rejection of low energy gammas by the detector is presented. The simplicity of construction and ruggedness of the detector are also discussed.
Keywords
Electrodes; Fission reactors; Gamma ray detection; Gamma ray detectors; Gamma rays; Inductors; Monitoring; Neutrons; Nickel; Power measurement;
fLanguage
English
Journal_Title
Nuclear Science, IEEE Transactions on
Publisher
ieee
ISSN
0018-9499
Type
jour
DOI
10.1109/TNS.1977.4328767
Filename
4328767
Link To Document