DocumentCode :
828639
Title :
Performance analysis of a PV powered health clinic with single-stage dual priority regulator
Author :
Salameh, Ziyad M. ; Lynch, William A.
Author_Institution :
Dept. of Electr. Eng., Lowell Univ., MA, USA
Volume :
6
Issue :
4
fYear :
1991
fDate :
12/1/1991 12:00:00 AM
Firstpage :
586
Lastpage :
592
Abstract :
The performance of a photovoltaic-powered health clinic system which uses two separate batteries, one to power a vaccine refrigerator and the other to power auxiliary loads is investigated. The two batteries were sized according to the demand of their loads. The power control system utilizes a single-stage dual-priority controller to charge the two separate batteries from a single photovoltaic array. The main refrigerator battery always has priority over the auxiliary battery, and therefore the use of auxiliary loads will never jeopardize the reliability of the critical load. This system provides power for auxiliary loads while utilizing the same number of photovoltaic modules as systems which power only a vaccine refrigerator. The performance of this system is evaluated using a data-acquisition system, and the experimental results are compared with their theoretical values
Keywords :
photovoltaic power systems; power control; refrigerators; PV powered health clinic; data-acquisition system; performance analysis; power auxiliary loads; power control system; reliability; single-stage dual priority regulator; vaccine refrigerator; Batteries; Control systems; Fuels; Performance analysis; Photovoltaic systems; Power system reliability; Refrigeration; Regulators; Solar power generation; Vaccines;
fLanguage :
English
Journal_Title :
Energy Conversion, IEEE Transactions on
Publisher :
ieee
ISSN :
0885-8969
Type :
jour
DOI :
10.1109/60.103629
Filename :
103629
Link To Document :
بازگشت