DocumentCode :
828775
Title :
Experience with turn insulation failures in large 13.2 kV synchronous motors
Author :
Walker, P. ; Champion, J.N.
Volume :
6
Issue :
4
fYear :
1991
fDate :
12/1/1991 12:00:00 AM
Firstpage :
670
Lastpage :
678
Abstract :
Experience of dealing with a very high rate of failures in a population of 21000 HP motors is recounted. Special testing done to identify the failure mechanism and the conclusions that were drawn are described. Various recommendations to prevent premature winding failures proved ineffective. It is shown how an engineering analysis indicated that the accepted view of the failure mechanism was untenable. A theory of partial discharge in the end turn of the stator winding that is compatible with all known facts is proposed
Keywords :
failure analysis; machine insulation; partial discharges; synchronous motors; 13.2 kV; 21000 hp; end turn; engineering analysis; failure mechanism; partial discharge; premature winding failures; stator winding; synchronous motors; testing; turn insulation failures; Coils; Failure analysis; Insulation; Production facilities; Stators; Stress; Surges; Synchronous motors; Testing; Voltage;
fLanguage :
English
Journal_Title :
Energy Conversion, IEEE Transactions on
Publisher :
ieee
ISSN :
0885-8969
Type :
jour
DOI :
10.1109/60.103640
Filename :
103640
Link To Document :
بازگشت