Title :
Beam Lifetime in the Initial Operation of KEK Main Ring
Author :
Ando, A. ; Araki, A. ; Endo, K. ; Igarashi, T. ; Kasuga, T. ; Kihara, M.
Author_Institution :
National Laboratory for High Energy Physics Oho-machi, Tsukuba-gun, Ibaraki, 300-32, Japan
fDate :
6/1/1977 12:00:00 AM
Abstract :
In the initial operation of the main ring of KEK PS, efforts have been put on improving the beam life by incorporating the correction lenses as well as reducing the emittance of the booster beam and the injection error. The transmission of 30 % at 0.5 sec after injection was obtained at the time of writing. This paper describes the performance of the main ring with respect to the beam life and discusses the problems to be solved.
Keywords :
Apertures; Error correction; Laboratories; Lattices; Lenses; Magnetic resonance; Magnets; Particle beams; Protons; Writing;
Journal_Title :
Nuclear Science, IEEE Transactions on
DOI :
10.1109/TNS.1977.4329000