DocumentCode :
829767
Title :
Transients in a Kramer Cascade
Author :
Wallach, Y. ; Erlicki, M.S. ; Ben-Uri, J.
Author_Institution :
TECHNION, Israel Institute of Technology
Issue :
2
fYear :
1966
fDate :
3/1/1966 12:00:00 AM
Firstpage :
158
Lastpage :
162
Abstract :
This paper discusses some transients in a modified Kramer-cascade, i.e., a cascade with the mechanical converter replaced by a diode rectifier bridge. First, a new method of starting the drive is described. It uses a single resistor in the armature circuit of the dc motor with the additional advantages of high starting torques at relatively low starting currents. Also, a rapid method for braking the drive is proposed with the braking effect being achieved by having both machines work as generators. Finally, since the drive may be used as part of a closed-loop system, its transfer function is calculated.
Keywords :
AC motors; Bridge circuits; DC motors; Diodes; Drives; Induction motors; Rectifiers; Resistors; Rotors; Torque;
fLanguage :
English
Journal_Title :
Industry and General Applications, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-943X
Type :
jour
DOI :
10.1109/TIGA.1966.4180638
Filename :
4180638