• DocumentCode
    830329
  • Title

    Method for calculating temperature rise in cables in bridge ducts

  • Author

    Kazama, Y. ; Ichiyanagi, N. ; Kasuya, M. ; Fujii, O.

  • Author_Institution
    Tokyo Electric Power Co. Inc., Japan
  • Volume
    6
  • Issue
    1
  • fYear
    1991
  • fDate
    1/1/1991 12:00:00 AM
  • Firstpage
    8
  • Lastpage
    14
  • Abstract
    To permit calculation of the power transmission capacity of cables carried in bridge ducts, methods for calculating the thermal resistance and capacity of a bridge and changes in the transient temperature of cables in bridge ducts are proposed. The validity of these methods is confirmed by tests on bridges. It is also found that the heat trapped in the duct can be estimated by a convection computation taking radiation into due consideration
  • Keywords
    engineering computing; power cables; temperature measurement; thermal analysis; bridge ducts; convection computation; heat radiation; power cables; power transmission capacity; temperature rise measurement; thermal resistance; Bridges; Cables; Ducts; Electrical resistance measurement; Power transmission; Solar radiation; Structural beams; Temperature; Testing; Thermal resistance;