• DocumentCode
    831961
  • Title

    Surge Protection for Pipeline Motors

  • Author

    Shankle, Derrill F. ; Edwards, Robert F. ; Moses, Graham L.

  • Author_Institution
    Westinghouse Electric Corporation
  • Issue
    2
  • fYear
    1968
  • fDate
    3/1/1968 12:00:00 AM
  • Firstpage
    171
  • Lastpage
    176
  • Abstract
    Recent field tests on motors in service on pipelines and powerhouse systems have shown that the switching surge voltage appearing at the motor terminals during initial energization for starting frequently reach magnitudes approaching 2.0 per unit normal crest line-to-ground operating voltage with time-to-crest as short as 0.2 As. This is more severe than normally believed and may endanger turn-to-turn insulation.
  • Keywords
    AC motors; Capacitance; Capacitors; Coils; Dielectrics and electrical insulation; Pipelines; Stress; Surge protection; Surges; Voltage;
  • fLanguage
    English
  • Journal_Title
    Industry and General Applications, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-943X
  • Type

    jour

  • DOI
    10.1109/TIGA.1968.4180873
  • Filename
    4180873