A Signal Analysis Method Using Cross-Correlation of Turbulence Flow Signals to Determine Calibration of Permanent Magnet Sodium Flowmeters
Author
Raptis, A.C. ; Forster, G.A.
Author_Institution
Components Technology Division Argonne National Laboratory Argonne, IL. 60439
Volume
25
Issue
1
fYear
1978
Firstpage
278
Lastpage
281
Abstract
Permanent magnet flowmeters are used to measure flow in sodium cooled power plants both in the core and in plant piping. In this paper the cross-correlation technique and in particular the transfer function method is used to process the flow turbulence signals from electrodes spaced along the pipe in the vicinity of the magnetic field. Results from a loop flowmeter the EBR-II secondary flowmeter and a 400 mm diameter flowmeter will be presented.
Keywords
Calibration; Fluid flow measurement; Magnetic cores; Magnetic field measurement; Permanent magnets; Power generation; Power measurement; Signal analysis; Signal processing; Transfer functions;