    A Signal Analysis Method Using Cross-Correlation of Turbulence Flow Signals to Determine Calibration of Permanent Magnet Sodium Flowmeters

  • Author

    Raptis, A.C. ; Forster, G.A.

  • Author_Institution
    Components Technology Division Argonne National Laboratory Argonne, IL. 60439
  • Volume
    25
  • Issue
    1
  • fYear
    1978
  • Firstpage
    278
  • Lastpage
    281
  • Abstract
    Permanent magnet flowmeters are used to measure flow in sodium cooled power plants both in the core and in plant piping. In this paper the cross-correlation technique and in particular the transfer function method is used to process the flow turbulence signals from electrodes spaced along the pipe in the vicinity of the magnetic field. Results from a loop flowmeter the EBR-II secondary flowmeter and a 400 mm diameter flowmeter will be presented.
  • Keywords
    Calibration; Fluid flow measurement; Magnetic cores; Magnetic field measurement; Permanent magnets; Power generation; Power measurement; Signal analysis; Signal processing; Transfer functions;