• DocumentCode
    832794
  • Title

    Commutation dv/dt Effects in Thyristor Three-Phase Bridge Converters

  • Author

    Rice, John B. ; Nickels, Lawrence E.

  • Author_Institution
    Allis-Chalmers Manufacturing Corporation
  • Issue
    6
  • fYear
    1968
  • Firstpage
    665
  • Lastpage
    672
  • Abstract
    A significant factor to be considered in properly designed thyristor converter circuits is dv/dt. The intent of this paper is to analyze a three-phase bridge circuit and show the following. 1) dv/dt faults due to turn-on transients are a threat only for operation in the inverter mode. 2) dv/dt faults due to the thyristor recovery transient are a threat for rectifier operation from about 50 to 0 percent of maximum dc output voltage (a between 60 and 90 degrees) as well as in the inverter mode. 3) dv/dt due to recovery is generally less severe and more easily suppressed than that due to turn-on. 4) Turn-on induced dv/dt can be calculated approximately by the use of simple equivalent circuits. 5) Recovery induced dv/dt can also be calculated if peak reverse current is known. 6) Thyristor critical dv/dt rating at 50 to 60 percent of rated anode voltage may be more useful than present standard ratings.
  • Keywords
    Anodes; Bridge circuits; Circuit faults; Commutation; Inductance; Inverters; Leg; Thyristors; Transient analysis; Voltage;
  • fLanguage
    English
  • Journal_Title
    Industry and General Applications, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-943X
  • Type

    jour

  • DOI
    10.1109/TIGA.1968.4180963
  • Filename
    4180963