• DocumentCode
    834126
  • Title

    Digital Simulaiion of a Commercial Scale High Temperature Gas-Cooled Reactor (HTGR) Steam Power Plant

  • Author

    Ray, Asok ; Bowman, H.Frederick

  • Author_Institution
    The MITRE Corporation, Bedford, Mass.
  • Volume
    25
  • Issue
    4
  • fYear
    1978
  • Firstpage
    1068
  • Lastpage
    1077
  • Abstract
    A nonlinear dynamic model of a commercial scale high temperature gas-cooled reactor (HTGR) steam power plant was derived in state-space form from fundamental principles. The plant model is 40th order, time-invariant, deterministic and continuous-time. Numerical results were obtained by digital simulation. Steady-state performance of the nonlinear model was verified with plant heat balance data at 100, 75 and 50 percent load levels. Local stability, controllability and observability were examined in this range using standard linear algorithms. Transfer function matrices for the linearized models were also obtained. Transient response characteristics of 6 system variables for independent step disturbances in 2 different input variables are presented as typical results. Simulation of the HTGR steam power plant provides the basis for (a) understanding the complex and highly interactive process dynamics, (b) designing an interactive multivariable controller, and (c) studying plant dynamic performance under various operating and upset conditions. Modeling and simulation techniques developed in the work from which this paper is abstracted have general applicability, and can be readily adapted to the study of gas-cooled steam power plants.
  • Keywords
    Controllability; Digital simulation; Inductors; Observability; Power generation; Power system modeling; Stability; Steady-state; Temperature; Transfer functions;
  • fLanguage
    English
  • Journal_Title
    Nuclear Science, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9499
  • Type

    jour

  • DOI
    10.1109/TNS.1978.4329470
  • Filename
    4329470