Title : 
Noncontacting Surface Thermometer for Rollers with Ambient-Temperature Compensation
         
        
            Author : 
Ohishi, Tadanao ; Ichijo, Bunjiro
         
        
            Author_Institution : 
National Research Laboratories of Metrology
         
        
        
        
        
        
            Abstract : 
The noncontacting thermometer for surface temperature measurement of rollers utilizing the radio frequency eddy current effect is described. A type of bridge is employed in this thermometer. The bridge detects a change in the resistivity of a roller material through the radio-frequency measuring coil. This thermometer has considerably improved accuracy with no time lag. The ambient-temperature influence is also compensated for. For example, the sensitivity of this thermometer is in most cases about 10 ¿A per °C, and the error in temperature was kept to less than 1 °C. Control of any arbitrarily desired temperature is possible through the use of this device.
         
        
            Keywords : 
Coils; Conductivity; Coupling circuits; Eddy currents; Inorganic materials; Radio frequency; Radiofrequency integrated circuits; Surface impedance; Surface resistance; Temperature measurement;
         
        
        
            Journal_Title : 
Industry and General Applications, IEEE Transactions on
         
        
        
        
        
            DOI : 
10.1109/TIGA.1970.4181244