Author :
Abe, K. ; Antilogus, P. ; Aston, D. ; Baird, K. ; Bean, A. ; Bienz, T. ; Bird, F. ; Caldwell, F.D. ; Cavalli-Sforza, M. ; Coyle, P. ; Coyne, D. ; Dasu, S. ; Dolinsky, S. ; d´Oliveira, A. ; Duboscq, J. ; Dunwoodie, W. ; Gagnon, P. ; Hallewell, G. ; Hasegaw
Author_Institution :
Dept. of Phys., Tohoku Univ., Sendai, Japan
Abstract :
The front-end electronics and data acquisition system for the SLD barrel Cherenkov ring imaging detector (CRID) are described. The specifications for this system require a 1% charge division measurement on single e/sup -/ pulses from a wire chamber in the presence of much larger signals. Fast recovery from saturating pulses and noise levels below 2000 electrons root-mean-square for single electron pulses are required. Noise and system performance results are presented for the initial SLD engineering run data.<>
Keywords :
Cherenkov counters; data acquisition; SLD Cherenkov ring imaging detector; charge division; data acquisition system; front end electronics; noise; saturating pulses; single e/sup -/ pulses; system performance; wire chamber; Charge measurement; Current measurement; Data acquisition; Detectors; Electrons; Noise level; Pulse measurements; Superluminescent diodes; System performance; Wire;