DocumentCode
836926
Title
SPND Operating Experience at Oconee Nuclear Station
Author
Curtis, Thomas D.
Author_Institution
Duke Power Company, Oconee Nuclear Station, P. O. Box 1175, Seneca, South Carolina 29678
Volume
26
Issue
1
fYear
1979
Firstpage
944
Lastpage
948
Abstract
This paper presents a comparative performance summary of the incore self-powered neutron detectors (SPND´s) used at Oconee through September, 1978. Data reported includes SPND replacement costs, detector failure records, background signal variations, and detector insulation current leakage resistances. The effects of SPND performance upon core power distribution measurements with the plant computer are discussed. Problems associated with concurrent use of SPND´s of different designs and irradiation times are addressed. The information presented should be useful to designers and users for selection and deployment of SPND´s.
Keywords
Costs; Detectors; Distributed computing; Electrical resistance measurement; Insulation; Leak detection; Neutrons; Power distribution; Power measurement; Signal detection;