• DocumentCode
    836926
  • Title

    SPND Operating Experience at Oconee Nuclear Station

  • Author

    Curtis, Thomas D.

  • Author_Institution
    Duke Power Company, Oconee Nuclear Station, P. O. Box 1175, Seneca, South Carolina 29678
  • Volume
    26
  • Issue
    1
  • fYear
    1979
  • Firstpage
    944
  • Lastpage
    948
  • Abstract
    This paper presents a comparative performance summary of the incore self-powered neutron detectors (SPND´s) used at Oconee through September, 1978. Data reported includes SPND replacement costs, detector failure records, background signal variations, and detector insulation current leakage resistances. The effects of SPND performance upon core power distribution measurements with the plant computer are discussed. Problems associated with concurrent use of SPND´s of different designs and irradiation times are addressed. The information presented should be useful to designers and users for selection and deployment of SPND´s.
  • Keywords
    Costs; Detectors; Distributed computing; Electrical resistance measurement; Insulation; Leak detection; Neutrons; Power distribution; Power measurement; Signal detection;
  • fLanguage
    English
  • Journal_Title
    Nuclear Science, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9499
  • Type

    jour

  • DOI
    10.1109/TNS.1979.4329749
  • Filename
    4329749