Abstract :
A general theory of measuring multiport networks is presented. In order to measure microwave multiport networks conveniently a method involving the stepwise reduction of the order of the network under test is suggested. All formulas for calibrating and measuring the triple six-port network analyzer, which is a universal six-port network analyzer, are given without any ambiguity. The procedures for calibration and measurement are very simple. No standard three-port network is needed to calibrate the six-port system. Finally, the error caused by nonideal isolation is discussed.<>
Keywords :
S-matrix theory; calibration; error analysis; measurement errors; microwave circuits; microwave measurement; multiport networks; network analysers; calibration; error analysis; measurement; microwave multiport networks; universal six-port network analyzer; Calibration; Gold; Isolators; Microwave measurements; Microwave theory and techniques; Performance analysis; Performance evaluation; Read only memory; Scattering parameters; Testing;