DocumentCode :
837316
Title :
Pressure drop of the ITER PFCI cable-in-conduit conductor
Author :
Marinucci, Claudio ; Bruzzone, Pierluigi ; Corte, Antonio Della ; Richard, Laura Savoldi ; Zanino, Roberto
Author_Institution :
Fusion Technol. Div., CRPP, Villigen, Switzerland
Volume :
15
Issue :
2
fYear :
2005
fDate :
6/1/2005 12:00:00 AM
Firstpage :
1383
Lastpage :
1386
Abstract :
Pressure drop in the ITER PFCI cable-in-conduit conductor (CICC) has been measured at CRPP using pressurized water at room temperature. The PFCI conductor is a dual channel CICC and the coolant flows in parallel in the central channel and in the annular bundle region. In our experiment the flow in the central channel is blocked and the longitudinal friction factor of the annular bundle region is deduced from measurements of pressure drop and mass flow rate. Two conductor samples are investigated, one with and one without subcable/outer cable wraps. The results show that the wraps have a negligible effect on the friction factor, and that the Katheder correlation overestimates the actual friction factor.
Keywords :
cable sheathing; flow measurement; friction; fusion reactor materials; pressure measurement; superconducting cables; ITER PFCI cable-in-conduit conductor; Katheder correlation; annular bundle region; coolant flows; dual channel CICC; friction factor; fusion reactor; mass flow rate; pressure drop; pressure measurement; pressurized water; subcable/outer cable wraps; superconducting cables; Conductors; Coolants; Friction; Helium; Niobium compounds; Pressure measurement; Superconducting cables; Temperature; Testing; Titanium compounds; Friction; fusion reactor; pressure measurement; superconducting cables;
fLanguage :
English
Journal_Title :
Applied Superconductivity, IEEE Transactions on
Publisher :
ieee
ISSN :
1051-8223
Type :
jour
DOI :
10.1109/TASC.2005.849096
Filename :
1439900
Link To Document :
بازگشت