DocumentCode :
837430
Title :
Estimation of Velocity Vectors in Synthetic Aperture Ultrasound Imaging
Author :
Jensen, Jorgen Arendt ; Oddershede, Niels
Author_Institution :
Center for Fast Ultrasound Imaging, Tech. Univ. Denmark, Lyngby
Volume :
25
Issue :
12
fYear :
2006
Firstpage :
1637
Lastpage :
1644
Abstract :
A method for determining both velocity magnitude and angle in a synthetic aperture ultrasound system is described. The approach uses directional beamforming along the flow direction and cross correlation to determine velocity magnitude. The angle of the flow is determined from the maximum normalized correlation calculated as a function of angle. This assumes the flow direction is within the imaging plane. Simulations of the angle estimation method show both biases and standard deviations of the flow angle estimates below 3deg for flow angles from 20deg to 90deg (transverse flow). The method is also investigated using data measured by an experimental ultrasound scanner from a flow rig. A commercial 128 element 7-MHz linear array transducer is used, and data are measured for flow angles of 60deg and 90deg. Data are acquired using the RASMUS experimental ultrasound scanner, which samples 64 channels simultaneously. A 20-mus chirp was used during emission and eight virtual transmit sources were created behind the transducer using 11 transmitting elements. Data from the eight transmissions are beamformed and coherently summed to create high-resolution lines at different angles for a set of points within the region of flow. The velocity magnitude is determined with a precision of 0.36% (60deg) and 1.2% (90deg), respectively. The 60deg angle is estimated with a bias of 0.54deg and a standard deviation of 2.1deg. For 90deg the bias is 0.0003deg and standard deviation 1.32deg. A parameter study with regard to correlation length and number of emissions is performed to reveal the accuracy of the method. Real time data covering 2.2 s of the carotid artery of a healthy 30-year-old male volunteer is acquired and then processed offline using a computer cluster. The direction of flow is estimated using the above mentioned method. It is compared to the flow angle of 106deg with respect to the axial direction, determined visually from the B-mode image. For a point in the center of th- - e common carotid artery, 76% of the flow angle estimates over the 2.2 s were within 10deg of the visually determined flow angle. The standard deviation of these estimates was below 2.7deg. Full color flow maps from different parts of the cardiac cycle are presented, including vector arrows indicating both estimated flow direction and velocity magnitude
Keywords :
biomedical ultrasonics; blood vessels; correlation methods; flow visualisation; haemodynamics; 2.2 s; 20 mus; 30 year; 7 MHz; B-mode image; RASMUS experimental ultrasound scanner; cardiac cycle; carotid artery; color flow maps; cross correlation; directional beamforming; flow direction; flow rig; linear array transducer; maximum normalized correlation; synthetic aperture ultrasound imaging; vector arrows; velocity magnitude; velocity vector estimation; Array signal processing; Biomedical imaging; Blood; Carotid arteries; Chirp; Fluid flow measurement; Goniometers; Ultrasonic imaging; Ultrasonic transducers; Ultrasonic variables measurement; Angle determination; medical ultrasound; synthetic aperture; vector velocity estimation;
fLanguage :
English
Journal_Title :
Medical Imaging, IEEE Transactions on
Publisher :
ieee
ISSN :
0278-0062
Type :
jour
DOI :
10.1109/TMI.2006.883087
Filename :
4016167