DocumentCode :
837749
Title :
Cryogenic Vacuum Pumping at the LBL 88-Inch Cyclotron
Author :
Elo, D. ; Morris, D. ; Clark, D.J. ; Gough, R.A.
Author_Institution :
Lawrence Berkeley Laboratory, Berkeley, California 94720, USA
Volume :
26
Issue :
2
fYear :
1979
fDate :
4/1/1979 12:00:00 AM
Firstpage :
2179
Lastpage :
2181
Abstract :
A cryogenic vacuum pumping panel has been in operation at the 88-inch cyclotron since 1974. The nude pumping panel is located in the acceleration chamber. The pumping surface consists of tubing cooled to 20°K by a closed loop helium refrigeration system. The pumping surfaces are shielded from radiation heat loads and water vapor by liquid nitrogen cooled baffles. The panel was designed for an average pumping speed of 14,000 liters/sec. for air. This approximately tripled the total effective pumping on the acceleration chamber from the existing diffusion pumped system, significantly reducing charge exchange losses of heavy ions during acceleration. Design, installation and performance characteristics will be described.
Keywords :
Acceleration; Copper; Cryogenics; Cyclotrons; Heat pumps; Helium; Nitrogen; Particle beams; Refrigeration; Water heating;