• DocumentCode
    839217
  • Title

    AGS Slow Extraction Improvements

  • Author

    Glenn, J.W. ; Smith, G.A. ; Sandberg, J.N. ; Repeta, L. ; Weisberg, H.

  • Volume
    26
  • Issue
    3
  • fYear
    1979
  • fDate
    6/1/1979 12:00:00 AM
  • Firstpage
    3167
  • Lastpage
    3169
  • Abstract
    Improvement of the straightness of the F5 copper septum increased the AGS slow extraction efficiency from ~ 80 percent to ~ 90 percent. Installation of an electrostatic septum at H20, 24 betatron wavelengths upstream of F5, further improved the extraction efficiency to ~ 97 percent.
  • Keywords
    Aging; Copper; Current measurement; Electrostatics; Extraterrestrial measurements; Length measurement; Magnets; Particle beams; Position measurement; Protons;
  • fLanguage
    English
  • Journal_Title
    Nuclear Science, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9499
  • Type

    jour

  • DOI
    10.1109/TNS.1979.4329972
  • Filename
    4329972