DocumentCode :
839235
Title :
The short-circuit characteristics of a DC reactor type superconducting fault current limiter with fault detection and signal control of the power converter
Author :
Ahn, Min Cheol ; Kang, Hyoungku ; Bae, Duck Kweon ; Park, Dong Keun ; Yoon, Yong Soo ; Lee, Sang Jin ; Ko, Tae Kuk
Author_Institution :
Dept. of Electr. & Electron. Eng., Yonsei Univ., Seoul, South Korea
Volume :
15
Issue :
2
fYear :
2005
fDate :
6/1/2005 12:00:00 AM
Firstpage :
2102
Lastpage :
2105
Abstract :
In general case of DC reactor type superconducting fault current limiter (SFCL), a fault current gradually increases during the fault. It takes above 5 cycles to cut off the fault in the existing power system installed the conventional circuit breakers (CBs). Therefore, the fault current increases during the fault even if the SFCL is installed. This paper proposes a technique for decaying the fault current with the function of the fault detection and control of power converter of the SFCL. Using the proposed method, the fault current can decay after 1-2 cycles when the fault occurs. To analyze this technique, three-phase 6.6 kV/200 A SFCL was fabricated. The SFCL has just one DC reactor, an AC to DC power converter which has thyristors as the rectifying device, and a three-phase transformer, which is called magnetic core reactor (MCR). The short-circuit tests of this SFCL were performed successfully. Comparing the result using the proposed technique with the typical result, the fault current is decreased effectively by the proposed technique. This result shows that this SFCL using the fault detection and control of power converter can be applied to the existing power system which has conventional CBs.
Keywords :
AC-DC power convertors; circuit breakers; fault current limiters; fault location; reactors (electric); rectifiers; superconducting devices; thyristors; transformers; AC to DC power converter; DC reactor type SFCL; circuit breakers; fault detection; magnetic core reactor; power converter control; power system; rectifying device; short-circuit characteristics; short-circuit test; signal control; superconducting fault current limiter; three-phase transformer; thyristors; Circuit breakers; Circuit faults; Electrical fault detection; Fault current limiters; Fault currents; Fault detection; Inductors; Magnetic analysis; Power system faults; Signal detection; DC reactor; fault detection; short-circuit characteristics; superconducting fault current limiter;
fLanguage :
English