Title :
Microprocessor Based Beam Loss Monitor System for the AGS
Author_Institution :
Brookhaven National Laboratory, Upton, New York 11973
fDate :
6/1/1979 12:00:00 AM
Abstract :
An array of 120 long radiation monitors (LRM) have been installed around the AGS. Each monitor is an extended coaxial ion chamber, 5 meters long, made from hollow core coaxial transmission cable pressured with argon. The LRM´s are each connected to a low current preamplifier and voltage-to-frequency converter (VFC). The digital output of each channel is fed to a 16 bit counter chip which bridges the bus of an 8085 microprocessor. This circuit is connected to the AGS PDP-10 for data taking or may function as a stand-alone unit. Various operating modes can be selected for data readout. System design and operating performance are described.
Keywords :
Circuits; Coaxial cables; Electronic equipment testing; Linear particle accelerator; Microprocessors; Monitoring; Radiation detectors; Signal to noise ratio; Structural beams; Voltage;
Journal_Title :
Nuclear Science, IEEE Transactions on
DOI :
10.1109/TNS.1979.4330020