Implementation and evaluation of a calculated attenuation correction for PET
Author :
Siegel, Stefan ; Dahlbom, Magnus
Author_Institution :
Dept. of Radiol. Sci., Sch. of Med., California Univ., Los Angeles, CA, USA
Volume :
39
Issue :
4
fYear :
1992
fDate :
8/1/1992 12:00:00 AM
Firstpage :
1117
Lastpage :
1121
Abstract :
The authors have developed a highly reliable and consistent method for automated calculated attenuation correction for positron emission tomography (PET). The method is based on estimating the object contour from the emission sinograms. The method relies on a robust algorithm to determine the border between activity and scatter background. The algorithm has been applied to brain studies with a variety of tracers and uptake distributions. The method has been tested in nearly 300 brain studies and shown to accurately find the object routine, regardless of the tracer used and the activity distribution. The method has been successfully extended for use in abdominal studies and with 3D acquisition data
Keywords :
brain; computerised tomography; radioisotope scanning and imaging; 3D acquisition data; PET; abdominal studies; activity distribution; attenuation correction; brain studies; emission sinograms; object contour; object routine; positron emission tomography; scatter background; tracers; uptake distributions; Abdomen; Attenuation measurement; Biomedical measurements; Head; Image reconstruction; Nuclear medicine; Pollution measurement; Positron emission tomography; Robustness; Scattering;
fLanguage :
English
Journal_Title :
Nuclear Science, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9499
Type :
jour
DOI :
10.1109/23.159770
Filename :
159770
Link To Document :
بازگشت