DocumentCode :
840567
Title :
Improved Chromticity Control for 100 GeV Storage at Fermilab
Author :
Ecklund, S. ; Gerig, R. ; MacLachlan, J. ; Pruss, S.
Author_Institution :
Fermi National Accelerator Laboratory Batavia, Illinois
Volume :
26
Issue :
3
fYear :
1979
fDate :
6/1/1979 12:00:00 AM
Firstpage :
3547
Lastpage :
3548
Abstract :
The current capability of the horizontal sextupole magnets in the main ring has recently been doubled. This allows the chromaticity to be adjusted to near zero at 100 GeV. Effects upon beam lifetime are discussed.
Keywords :
Apertures; Contracts; Educational institutions; Magnets; Phase measurement; Power supplies; Research and development; Scattering; Storage rings;
fLanguage :
English
Journal_Title :
Nuclear Science, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9499
Type :
jour
DOI :
10.1109/TNS.1979.4330095
Filename :
4330095
Link To Document :
بازگشت